SealBoss R70 Pump Flush
Pump Flush | Cleaner & Conditioner
SealBoss ® R70 Pump Flush & Cleaner Advantages
- NOT a Solvent – 100% Solvent Free
- Non-Flammable
- No Shipping Hazard Class
- Conditions Pump Seals and Hoses
UNITS: 1GAL, 5 GAL, DRUMS, TOTES
Product Description
SealBoss R70 Pump Flus
Cleaning Guidelines
Step One – Purge
Purge the system of the injection material used.
Step Two – Flush
Pump cleaning should be approached and performed with two phases in mind. Initially, and only if in compliance with all applicable regulations on the job site (!), the clearing of residual material may be done with a very small amount of solvent that is compatible with the product. Follow all instructions and steps that are necessary to be in compliance with use of the solvent. Please note that the chemical composition of solvents may harm the integrity of seals, gaskets and hoses of the pump. Immediately following the initial purge, use necessary amounts of SealBoss R70 Pump Flush & Cleaner to rid the pump of any residual solvents and product. Discard of the liquid. Do not recirculate at this point.
Step Three – Recirculate
After the majority of grout has been purged and flushed from the system use enough SealBoss R70 Pump Flush & Cleaner for at least five (5) minutes at a higher pressure setting and recirculate the product. Open and close the shut-off valve several times quickly to build up pressure and allow for high velocity flow of cleaning liquid. This process will help condition the gaskets, hose interiors, etc., prolonging the lifespan of your investment. You may keep a residual amount of clean SealBoss R70 Pump Flush & Cleaner in the system as lubricant. These are guidelines only without any claim of completeness assuming the use of products supplied by SealBoss Corp. Your conditions may call for modified and even more extensive cleaning efforts. Please watch video above for more information.